The Environment screen in VYROX Quarry (AIKuari) keeps the quarry inside its dust, noise and water limits and shows the evidence. It checks PM10 against the site trigger and the Malaysian Ambient Air Quality Standard (MAAQS 2020), shows day noise and settling pond discharge against their limits, and switches sprinklers on by a dust and wind rule. HSE officers and quarry managers use it daily and for regulator reports.
Stat Cards
Open Environment from the Site-Wide group.
| Card | What It Shows | Sample Limit Shown |
|---|---|---|
| PM10, Village Side | 1-hour PM10 at the monitor nearest the homes | Trigger 150 · MAAQS 24 h 100 |
| PM10, Plant Gate | 1-hour PM10 at the plant gate | None shown |
| Noise, Day | Day noise in dBA | Suburban day limit 65 dBA |
| Pond Discharge | Suspended solids (TSS) in mg/L | Standard B 100 mg/L |
The product also describes PM2.5, night noise by zone and pond pH against Standard A and B.
The Dust Rule and Sprinklers
The Dust Rule · North Quarry card shows whether sprinklers are on and why. All three conditions must be true to switch on:
- The PM10 1-hour average is over the trigger (150 µg/m³ in the demo).
- The wind is from within 45° of the village bearing, so it blows toward the village.
- The wind speed is at least 1 m/s.
Each condition is listed with a tick or a cross. When the rule fires, the command is queued for the site gateway and the Event Log records "Sprinklers switched ON automatically (dust rule)". In the demo the sprinklers switch off once PM10 is below 90 µg/m³ and they have run 30 minutes.
| Badge or Label | Meaning |
|---|---|
| Armed | The rule is watching and will act when all three conditions are true |
| Rule Active | The rule has switched the sprinklers on |
| Sprinklers ON / Sprinklers OFF | The current sprinkler state |
In the demo, sliders for PM10, Wind From and Wind Speed let you see how the rule decides.
Wind and the Village
The Wind and the Village card shows a compass with the village direction, the 45° window either side, and where the wind is blowing. Below it, the Event Log lists rain and sprinkler events with their times.
Settling Ponds and Water
- Level sensors on ponds, sumps and tanks report levels.
- Pond Discharge shows suspended solids against the discharge standard.
- The product describes IO controllers running pumps from level readings.
Devices Used
Dust and Noise Station (VX-EN200), Weather Station (VX-WS500), IO Controller (VX-IO300), Pipe Pressure Sensor (VX-PP500), Solar Gateway (VX-GW500S), Submersible Level Sensor (VX-WL500), Ultrasonic Level Sensor (VX-UL400) and Radar Level Sensor (VX-RL410).
Frequently Asked Questions
Which Standards Are Used?
MAAQS 2020 for dust, zone limits for noise, and Standard A and B for effluent, as set on the Limits page for your site.
Why Did the Sprinklers Not Start When Dust Was High?
All three conditions must be true. If the wind was blowing away from the village, or was too light, the rule does not switch on.
Can I Ask About Dust in Plain Words?
Yes. Ask AI answers "How is the dust at North Quarry?" with the figures against the standard.