Skip to content
← Back to guide Blasting

AISERVA and AIKuari · AISERVA and AIKuari: Local AI Guide

Blasting

VYROX Wiki · Updated 23 September 2026 · https://www.vyrox.com/wiki/aikuari-blasting

Blasting in VYROX Quarry (AIKuari) records the ground vibration (PPV) and air overpressure of every blast at the nearest homes, checks each against the limits on the Limits page, and keeps a register of the month's blasts. The product also links community complaints to the blast behind them. Quarry managers, blasting supervisors and HSE officers use it to show compliance.

Note

This guide is based on the AIKuari (VYROX Quarry) demo, which runs on sample data for a fictional company, Demo Quarry Sdn Bhd. Every figure shown is a sample value, not a measured result or a guarantee. Screens, labels, limits and menus may differ in a live deployment, depending on how VYROX sets up your sites and your role.

The Blast Card

Open Blasting from The Chain group. The blast card, for example Blast B-2026-014 · Bench 3, North Quarry, shows the latest blast.

ItemWhat It MeansSample Value
FiredTime of the blast09:30
Nearest receptorThe nearest homes and their distance from the benchKampung houses 320 m from the bench
Ground Vibration (PPV)Peak particle velocity at the receptor, shown as a meter against its limit4.8 of 5.0 mm/s
Air OverpressureAir blast at the receptor, shown as a meter against its limit118 of 120 dBL

Below the meters, a table lists each Reading with its Value, Limit and Status, including Oversize at Crusher Feed from the crusher-feed camera. Status badges include Inside, Inside, Unconfirmed and Crusher Warned.

Before a blast is fired, the card says no blast has happened yet today and lists recent blasts.

Limits

Limits come from the Limits page, set up with VYROX for your site. If a limit has not been confirmed, the screen says so, for example the air overpressure limit shows as "(unconfirmed)".

Warning

Treat any blast over its limit as a compliance event. Follow your site's reporting procedure and your permit conditions.

Register This Month

The Register This Month card lists each blast with Blast, Date, PPV mm/s, Air dBL and Status. A blast over its limit is marked Over the Limit. You can also ask Ask AI "Were any blasts over the vibration limit this month?"

After the Blast

  • Oversize rock: the crusher-feed camera measures the share of oversize rock, and the crusher is warned before it chokes.
  • Feed shortage: stops on the crushing line after a blast appear under the reason "Feed shortage after blast" on the Crushing screen.
  • Complaints: the product links complaints from the village to the blast behind them.

Devices Used

Blast Vibration Monitor (VX-SG100) at the receptor, Weather Station (VX-WS500) for blast planning, Tilt Sensor (VX-TL320) on slopes and bench edges, and AI PTZ Camera (VX-PT200) over the pit. See VYROX Quarry Devices.

Frequently Asked Questions

Is Every Blast Recorded?

The Blast Vibration Monitor is designed to record every blast, and each recorded blast is checked against the limits.

Where Do the Limits Come From?

From the Limits page, set up with VYROX for your site.

Can I Export Blast Data?

Reports can be exported to CSV. Ask VYROX which blast fields are included in your deployment.

Related Guides

  • Environment, Dust, Noise and Settling Ponds
  • Crushing and Conveyors
  • Alarms